瓦斯安全監(jiān)控系統(tǒng)故障應(yīng)急預(yù)案
20**年4月30日
目錄
1事故類型和危害程度分析·································3
1.1危險源評估··········································
1.2事故類型和危害程度分析·······························3
2應(yīng)急處置基本原則······································
3組織機(jī)構(gòu)及職責(zé)········································5
3.1應(yīng)急組織機(jī)構(gòu)·········································5
3.2應(yīng)急機(jī)構(gòu)及職責(zé)·······································5
4防范措施·············································5
5發(fā)生事故后的處理措施···································7
6報警應(yīng)急處理預(yù)案····················7
7信息報告程序····················19
7.1報警程序········································19
7.2接警、記錄程序······································19
7.3通知程序············································20
8事故的分級····································20
9應(yīng)急響應(yīng)21
9.1Ⅰ級特別重大故障事件響應(yīng)·····························21
9.2Ⅱ級故障事件響應(yīng)······································22
10應(yīng)急保障···········································22
11培訓(xùn)和演習(xí)······································23
12事故后期調(diào)查····································23
附件····································23
瓦斯安全監(jiān)控系統(tǒng)故障應(yīng)急預(yù)案
1事故類型和危害程度分析
1.1危險源評估
我礦存在的瓦斯隱患評估
根據(jù)20**年度礦井瓦斯鑒定結(jié)果,我礦為低瓦斯礦井。礦井瓦斯相對涌出量為2.35m3/t,絕對涌出量為1.78m3/t。屬于低瓦斯礦井,。20**年度瓦斯等級鑒定工作已經(jīng)完成,報告已批復(fù)。
我礦堅持瓦斯治理的十二字方針,建立了完善的監(jiān)測監(jiān)控系統(tǒng),該系統(tǒng)選用了北京中煤安泰有限公司研發(fā)的KJ78N型監(jiān)控系統(tǒng),系統(tǒng)具有組網(wǎng)性能先進(jìn)、監(jiān)測數(shù)據(jù)準(zhǔn)確可靠、巡檢周期短、傳輸速率快的特點(diǎn)。
現(xiàn)井下安全監(jiān)測系統(tǒng)已覆蓋井下盤區(qū)的所有采掘工作面,覆蓋率達(dá)100%,其中綜采工作面配備皮帶開停、斷電狀態(tài)傳感器、風(fēng)門開閉和瓦斯傳感器,掘進(jìn)工作面配備皮帶開停、斷電狀態(tài)傳感器、風(fēng)機(jī)開停和瓦斯傳感器,并對所有的采掘工作面實(shí)現(xiàn)了瓦電閉鎖。
我礦屬于低瓦斯礦井,一旦發(fā)生瓦斯爆炸事故,直接威脅礦井的安全生產(chǎn),會造成極大的損失。
1.2事故類型和危害程度分析
1)、由于地面中心站故障(軟件、硬件或病毒感染)導(dǎo)致整個系統(tǒng)癱瘓;
2)、由于監(jiān)測分站故障導(dǎo)致區(qū)域性信號無法正常監(jiān)測;
3)、由于傳感器、斷電器等調(diào)校不準(zhǔn)或故障導(dǎo)致無法正常監(jiān)測,發(fā)生誤報、漏報或閉鎖誤動作、不動作;
4)、由于傳輸線路短路、抽線或其他原因?qū)е碌孛嬷行恼緹o法監(jiān)測、監(jiān)控現(xiàn)場設(shè)備;
應(yīng)急處置的原則
1、預(yù)防為主
堅持“安全第一、預(yù)防為主”的方針,加強(qiáng)監(jiān)控系統(tǒng)安全管理,落實(shí)國家《煤礦安全規(guī)程》和省、市安全生產(chǎn)監(jiān)督管理局等關(guān)于瓦斯監(jiān)測監(jiān)控系統(tǒng)的文件、管理辦法和規(guī)定,做好隱患控制措施,有效防止監(jiān)測監(jiān)控系統(tǒng)重大事故發(fā)生,加強(qiáng)監(jiān)測監(jiān)控設(shè)施保護(hù)宣傳工作的力度,提高職工的保護(hù)意識,使用和管理好監(jiān)測監(jiān)控設(shè)施,制訂科學(xué)有效的故障恢復(fù)預(yù)案,開展事故緊急處置演習(xí),提高本部門應(yīng)對突發(fā)事件的能力。
2、統(tǒng)一指揮
在通風(fēng)部門統(tǒng)一指揮和協(xié)調(diào)下,通過應(yīng)急指揮機(jī)構(gòu)和調(diào)度機(jī)構(gòu),組織開展事故處理、事故搶險,系統(tǒng)恢復(fù)應(yīng)急救援等各項應(yīng)急工作。
3、分工負(fù)責(zé)
按照統(tǒng)一協(xié)調(diào),各負(fù)其責(zé)的原則,建立事故應(yīng)急處理體系,按照各管轄范圍,制定和完善系統(tǒng)應(yīng)急處理和恢復(fù)預(yù)案,保證系統(tǒng)盡快恢復(fù)運(yùn)行,各使用單位必須完善監(jiān)控系統(tǒng)故障期間的安全措施,避免在監(jiān)控系統(tǒng)故障期間發(fā)生災(zāi)害。
4、保證重點(diǎn)
在系統(tǒng)事故處理和控制過程中,將保證掘進(jìn)、回采工作面的安全放在首要位置,采取各種手段防止事故的進(jìn)一步擴(kuò)大,將故障控制在最小范圍。
組織機(jī)構(gòu)
3.1、成立安全監(jiān)測監(jiān)控系統(tǒng)重大故障應(yīng)急領(lǐng)導(dǎo)組,統(tǒng)一領(lǐng)導(dǎo)監(jiān)測監(jiān)控系統(tǒng)故障應(yīng)急處置工作,應(yīng)急辦公室設(shè)在調(diào)度室。
領(lǐng)導(dǎo)組由礦總工程師、通風(fēng)科長、調(diào)度主任、機(jī)電科長、監(jiān)測組長等組成。
組長:
副組長:
組員:
3.2、應(yīng)急機(jī)構(gòu)負(fù)責(zé)處理應(yīng)急工作,完善應(yīng)急救援處置體系(生產(chǎn)調(diào)度、機(jī)電科、通用科、監(jiān)測組)。機(jī)電科負(fù)責(zé)供電安全,瓦檢隊負(fù)責(zé)瓦斯安全檢查,監(jiān)測組負(fù)責(zé)事故處理。
防范措施
1)、傳感器報警濃度、斷電濃度、復(fù)電濃度和斷電范圍必須符合《煤礦安全規(guī)程》有關(guān)規(guī)定。整定后的傳感器非專職調(diào)校人員不得在井下拆卸或調(diào)整。
2)、安全生產(chǎn)監(jiān)測系統(tǒng)地面主機(jī)部分專人專管、專機(jī)專用,嚴(yán)禁將主備機(jī)和服務(wù)器用作他用;嚴(yán)禁利用主備機(jī)和服務(wù)器上網(wǎng)或其他任何工作;系統(tǒng)必須備足相關(guān)備品、備件。
3)、安全監(jiān)控設(shè)備的供電電源必須取自被控制開關(guān)的電源側(cè),嚴(yán)禁接在被控開關(guān)的負(fù)荷側(cè)。拆除或改變與安全監(jiān)控設(shè)備關(guān)聯(lián)的電氣設(shè)備的電源線及控制線、檢修與安全監(jiān)控設(shè)備關(guān)聯(lián)的電氣設(shè)備、需要安全監(jiān)控設(shè)備停止運(yùn)行時,須報告礦調(diào)度室,并制定安全措施后方可進(jìn)行。
4)、安全監(jiān)控設(shè)備每月至少進(jìn)行1次調(diào)試、校正。甲烷傳感器每7天必須使用校準(zhǔn)氣樣和空氣樣調(diào)校1次。每7天必須對甲烷超限斷電功能進(jìn)行測試。
5)、安全監(jiān)控設(shè)備發(fā)生故障或停電檢修時,必須及時處理,在故障期間必須具有安全措施。
6)、瓦斯斷電器必須按規(guī)定吊掛在配電點(diǎn)上方,電纜吊掛整齊,接線附件必須符合完好標(biāo)準(zhǔn)。任何人不得以任何理由甩掉遠(yuǎn)動開關(guān)或甩掉控制線路。串聯(lián)風(fēng)時,所用的瓦斯斷電器要控制風(fēng)機(jī)開關(guān)。
7)、使用單位必須每天派人對所使用的瓦斯斷電器及閉鎖開關(guān)進(jìn)行檢查,發(fā)現(xiàn)問題及時處理,禁止將閉鎖開關(guān)的控制回路的保護(hù)裝置甩掉,不準(zhǔn)隨便改變閉鎖開關(guān)控制回路的電壓電流參數(shù),嚴(yán)禁不通過瓦斯斷電器閉鎖供電。
8)、瓦斯超限時,瓦斯斷電器動作實(shí)現(xiàn)斷電。當(dāng)瓦斯數(shù)值降至復(fù)電值時,必須用啟動按鈕復(fù)電,禁止采用其它方式復(fù)電。
9)、任何單位和個人不得任意改變安全監(jiān)測和人員監(jiān)測設(shè)備的位置、中斷監(jiān)測設(shè)備的運(yùn)行,不得損壞監(jiān)測設(shè)備。
10)、安全監(jiān)控系統(tǒng)的系統(tǒng)調(diào)整、地址修改由信息中心專職技術(shù)人員按礦生產(chǎn)接續(xù)要求進(jìn)行,其它人一律不得擅自執(zhí)行、調(diào)整。修改時必須經(jīng)礦總工程師批準(zhǔn)方可執(zhí)行。
5發(fā)生事故后的處理措施
1)、地面中心站出現(xiàn)故障,必須立即組織人員搶修。如硬件故障,備用設(shè)備立即投入使用;系統(tǒng)恢復(fù)正常后,必須分析故障原因,查找存在隱患,同時對故障設(shè)備及時維修或補(bǔ)齊。軟件原因造成故障,事后能重心安裝的要重新安裝,不能安裝的要聯(lián)系廠家處理。
2)、監(jiān)控分站故障后,立即組織備用分站下井更換,同時匯報相關(guān)領(lǐng)導(dǎo)和部門作好應(yīng)急準(zhǔn)備;
3)、傳感器或斷電器出現(xiàn)問題后,立即通知責(zé)任單位更換,并查找原因分析處理。
4)、由于傳輸線路原因造成故障的,立即組織人員排查,短時間無法恢復(fù)的,立即更換新纜線,確保最短時間內(nèi)恢復(fù)正常狀態(tài)。
6報警應(yīng)急處理預(yù)案
隨著我礦信息化建設(shè)的不斷深入,安全監(jiān)測監(jiān)控系統(tǒng)在我礦的安全生產(chǎn)中發(fā)揮的作用日顯重要,與安全生產(chǎn)的聯(lián)系也越來越緊密。為了保證在安全監(jiān)控報警的初期,就把現(xiàn)場存在的安全隱患有效解決處理,不至于發(fā)生重大惡性事故,因此根據(jù)上級的有關(guān)指示規(guī)定,特編制《宏大隆博煤業(yè)安全監(jiān)控系統(tǒng)報警應(yīng)急預(yù)案》。
一、礦屬各單位的職責(zé)范圍:
(一)信息中心:
1、負(fù)責(zé)監(jiān)測監(jiān)控系統(tǒng)運(yùn)行的維護(hù)和管理工作,確保系統(tǒng)24小時穩(wěn)定運(yùn)行,信息準(zhǔn)確可靠。
2、負(fù)責(zé)監(jiān)測系統(tǒng)傳感器的調(diào)校、維修、以及設(shè)備的領(lǐng)用、保管及發(fā)放工作,并對傳感器、電纜等相關(guān)設(shè)備統(tǒng)一編號、建帳、轉(zhuǎn)帳、消帳,做到數(shù)量清、狀態(tài)明,帳、物相符。負(fù)責(zé)向通風(fēng)科提報監(jiān)測系統(tǒng)年度計劃。
3、在調(diào)度室、通風(fēng)科的指導(dǎo)下對系統(tǒng)的測點(diǎn)進(jìn)行設(shè)置,負(fù)責(zé)采掘工作面、機(jī)電硐室的監(jiān)測系統(tǒng)的設(shè)計、安裝和撤除工作;其中斷電器與被控開關(guān)的觸點(diǎn)連接由使用單位負(fù)責(zé),各分站供電電源由本地點(diǎn)用電單位負(fù)責(zé)提供。負(fù)責(zé)地面通訊主干線路的安裝維護(hù);負(fù)責(zé)礦井風(fēng)門傳感器的安裝與撤除工作。
4、在信息中心設(shè)信息調(diào)度對監(jiān)測監(jiān)控系統(tǒng)進(jìn)行專題調(diào)度,當(dāng)系統(tǒng)出現(xiàn)的故障時,要迅速判斷故障范圍,現(xiàn)場問題及時通知調(diào)度室、通風(fēng)區(qū)和使用單位進(jìn)行處理,系統(tǒng)主干線路故障要在短時間內(nèi)組織排除。
5、信息中心要對各使用單位所負(fù)責(zé)安全傳感器設(shè)備進(jìn)行監(jiān)督檢查,對不符合要求的有權(quán)按有關(guān)規(guī)定進(jìn)行處罰。
(二)機(jī)電科:
作為我礦機(jī)電主管部門,對涉及信息化、自動化的機(jī)電管理,與信息中心共同管理,并負(fù)責(zé)對井下供電系統(tǒng)監(jiān)測的測點(diǎn)安裝、撤除、轉(zhuǎn)移進(jìn)行業(yè)務(wù)指導(dǎo),并提供相關(guān)資料和圖紙;通過計算機(jī)網(wǎng)絡(luò)對安全生產(chǎn)監(jiān)測系統(tǒng)的相關(guān)信息進(jìn)行監(jiān)視,對供電系統(tǒng)出現(xiàn)的故障及時組織處理;按照通防要求及范圍,提供采煤工作面、掘進(jìn)工作面、機(jī)電硐室及其它地點(diǎn)的瓦斯斷電設(shè)計及設(shè)備的斷電端口。
(三)調(diào)度室:
作為全礦安全生產(chǎn)指揮中心,通過調(diào)度大屏及監(jiān)視器所反映的各種安全生產(chǎn)信息進(jìn)行調(diào)度指揮。系統(tǒng)測點(diǎn)的安裝、撤除、增加和轉(zhuǎn)移由調(diào)度室在平衡安全生產(chǎn)布局的情況下確定;當(dāng)系統(tǒng)出現(xiàn)的異常信息、報警信息或圖像、監(jiān)控數(shù)據(jù)異常要及時通知信息中心、通風(fēng)科、井下現(xiàn)場、相關(guān)區(qū)隊及有關(guān)部門或單位進(jìn)行處理。
(四)通風(fēng)科:
1、通風(fēng)科值班員負(fù)責(zé)通過計算機(jī)監(jiān)測監(jiān)控系統(tǒng)時刻對礦井通風(fēng)、瓦斯、防火方面的相關(guān)信息進(jìn)行監(jiān)視,發(fā)現(xiàn)瓦斯、一氧化碳超限、一組風(fēng)門同時敞開、風(fēng)機(jī)停電等異常情況時,必須及時安排有關(guān)人員現(xiàn)場處理,并分析事故原因,對監(jiān)測監(jiān)控系統(tǒng)存在的問題及時通知調(diào)度室組織處理。
2、落實(shí)瓦檢員在巡檢過程中,對巡檢范圍內(nèi)傳感器的運(yùn)行狀態(tài)和顯示數(shù)據(jù)進(jìn)行檢查和核對,對安全傳感器所在區(qū)域的氣體進(jìn)行檢查,發(fā)現(xiàn)傳感器顯示的數(shù)據(jù)與現(xiàn)場實(shí)際氣體誤差較大時,要立即匯報通風(fēng)區(qū),由通風(fēng)區(qū)調(diào)度員負(fù)責(zé)通知信息中心進(jìn)行調(diào)校或更換,以保證監(jiān)測數(shù)據(jù)準(zhǔn)確、可靠。
3、通風(fēng)區(qū)作為全礦一通三防管理工作的技術(shù)業(yè)務(wù)部門,根據(jù)礦井生產(chǎn)需要,對通防方面的安全監(jiān)控系統(tǒng)管理工作進(jìn)行技術(shù)指導(dǎo)和監(jiān)督,對監(jiān)測系統(tǒng)傳感器、斷電儀等裝置的架設(shè)位置、測量范圍、斷電濃度和斷電范圍以及生產(chǎn)過程中的安裝、撤除和移動,進(jìn)行業(yè)務(wù)指導(dǎo),并提供相關(guān)圖紙。每月5日前向信息中心提報月度安全傳感器安設(shè)計劃;負(fù)責(zé)對監(jiān)測系統(tǒng)年度計劃進(jìn)行匯總并上報。
(五)運(yùn)轉(zhuǎn)工區(qū):
負(fù)責(zé)對便攜式甲烷報警儀等安全檢測設(shè)備進(jìn)行定期調(diào)校、維修和測試,確保測定數(shù)據(jù)及報警點(diǎn)準(zhǔn)確、可靠,報警聲音強(qiáng)足夠大。
(六)使用單位:
負(fù)責(zé)監(jiān)測系統(tǒng)分站以里的所有設(shè)備,包括傳感器、閉鎖裝置、纜線等由使用單位負(fù)責(zé)安裝、維護(hù)、撤除。
二、瓦斯傳感器報警應(yīng)急預(yù)案
礦調(diào)度臺、通風(fēng)區(qū)、信息中心必須24小時對安全監(jiān)測監(jiān)控系統(tǒng)進(jìn)行時刻監(jiān)控,當(dāng)系統(tǒng)出現(xiàn)的異常信息、報警信息或圖像、監(jiān)控數(shù)據(jù)異常要及時通知信息中心、通風(fēng)區(qū)、井下現(xiàn)場、相關(guān)區(qū)隊及有關(guān)部門或單位進(jìn)行檢查處理。
(一)瓦斯傳感器調(diào)校測試報警:
信息中心在對井下瓦斯傳感器進(jìn)行正常調(diào)校和測試之前,必須提前匯報調(diào)度室及通風(fēng)區(qū),如未匯報調(diào)度室及通風(fēng)區(qū)就擅自進(jìn)行調(diào)校和測
試造成一定后果的,要按事故進(jìn)行分析。
(二)瓦斯傳感器報警:
當(dāng)安全監(jiān)測監(jiān)控系統(tǒng)瓦斯傳感器報警時,信息中心要立即通知礦調(diào)度室及通風(fēng)區(qū),并要立即調(diào)查造成報警的原因,同時通風(fēng)區(qū)調(diào)度員要立即聯(lián)系井下瓦斯檢查員對現(xiàn)場瓦斯情況進(jìn)行測定,并將測定的結(jié)果匯報通風(fēng)調(diào)度室,然后由通風(fēng)區(qū)調(diào)度員將井下測量結(jié)果反饋給調(diào)度室及信息中心。
1、如果測量的瓦斯情況正常,則說明是安全監(jiān)測監(jiān)控系統(tǒng)信號線和電源線出現(xiàn)線路故障,此時信息中心要立即分析、查找故障原因,確定故障范圍。
(1)屬于信息中心責(zé)任范圍的,信息中心應(yīng)立即組織人員解決處理,不得以任何理由拖延處理時間。超過2小時未處理完畢的,對信息中心罰款100元。
(2)屬于其他單位責(zé)任范圍的,信息中心應(yīng)嚴(yán)格按照故障處理程序通知責(zé)任單位處理。責(zé)任單位必須在接到通知后立即組織處理,不得以任何理由拖延處理時間。超過2小時未處理完畢的,對責(zé)任單位罰款100元。
2、如果實(shí)屬瓦斯超限報警時,首先通風(fēng)區(qū)要立即分析引起瓦斯超限的原因,并由瓦斯檢查員向礦調(diào)度室及通風(fēng)區(qū)詳細(xì)匯報井下具體情況,通風(fēng)區(qū)在了解具體情況后,再根據(jù)現(xiàn)場實(shí)際,采用相應(yīng)的處理方法。
(1)、井下采掘工作面風(fēng)流中及其作業(yè)地點(diǎn)瓦斯?jié)舛冗_(dá)到1.0%時:
①現(xiàn)場管理人員和班組長立即組織現(xiàn)場作業(yè)人員停止作業(yè),并立即匯報礦調(diào)度室,由瓦斯檢查員對現(xiàn)場的氣體情況和瓦斯探頭進(jìn)行檢查和比較,(瓦檢員不在現(xiàn)場,由區(qū)隊兼職瓦檢員檢查)。
②瓦斯檢查員在查明現(xiàn)場氣體情況確認(rèn)后立即將現(xiàn)場實(shí)際情況匯報礦調(diào)度室和通風(fēng)工區(qū)值班人員,然后到現(xiàn)場與安監(jiān)員一起對現(xiàn)場的氣體情況進(jìn)行監(jiān)護(hù)并及時向調(diào)度室匯報。
③安全監(jiān)測系統(tǒng)值班員發(fā)現(xiàn)井下濃度達(dá)到1.0%瓦斯傳感器超限報警后,立即向礦調(diào)度室和通風(fēng)工區(qū)值班人員匯報,并做好超限地點(diǎn)、時間的記錄,時刻注意觀察超限地點(diǎn)瓦斯變化情況。
④礦調(diào)度室值班人員接到匯報后,將超限的地點(diǎn)、時間、匯報人的姓名、現(xiàn)場的氣體情況作詳細(xì)的記錄。
⑤值班調(diào)度員立即通知通風(fēng)工區(qū)值班人員下井組織查明原因。
⑥值班調(diào)度員立即匯報礦值班領(lǐng)導(dǎo)、礦通防副總、礦總工程師。
⑦施工單位區(qū)長和通風(fēng)工區(qū)區(qū)長及有關(guān)人員接到報警通知后立即到調(diào)度室集合,成立現(xiàn)場事故處理小組,由礦總工程師立即召*議,對現(xiàn)場的情況進(jìn)行分析,在通風(fēng)工區(qū)值班人員到現(xiàn)場查明原因?qū)F(xiàn)場實(shí)際情況匯報礦調(diào)度室后,由通風(fēng)工區(qū)區(qū)長制定處理措施,匯報總工程師同意后,負(fù)責(zé)組織實(shí)施。
(2)、井下采掘工作面風(fēng)流中及其作業(yè)地點(diǎn)瓦斯?jié)舛冗_(dá)到1.5%時:
①現(xiàn)場管理人員和安監(jiān)員負(fù)責(zé)組織將所有作業(yè)人員停止工作,人員撤離到全風(fēng)壓通風(fēng)的采區(qū)進(jìn)風(fēng)巷或主要進(jìn)風(fēng)巷中,由班組長安排專人負(fù)責(zé)在巷道全風(fēng)壓風(fēng)流處設(shè)置警標(biāo)牌進(jìn)行警戒,嚴(yán)禁人員入內(nèi),把便攜式瓦斯檢測報警儀懸掛在巷道警標(biāo)牌處(距頂板不大于300mm,距巷幫不小于200mm),由警戒人員檢測瓦斯?jié)舛取2R報礦調(diào)度室。
②立即通知其他距離較近人員迅速撤離到主要進(jìn)風(fēng)巷道中。
③安全監(jiān)測系統(tǒng)必須切斷采掘工作面所有非本安電氣設(shè)備的電源(如安全監(jiān)測系統(tǒng)不能切斷電源,現(xiàn)場作業(yè)人員必須手動切斷所有電源)。
④安全監(jiān)測系統(tǒng)地面中心站要記錄好超限斷電時間和瓦斯變化情況及時向礦調(diào)度室匯報。
⑤礦調(diào)度室值班人員接到井下的匯報后,將超限的地點(diǎn)、時間、匯報人的姓名、現(xiàn)場的氣體情況作詳細(xì)的記錄。
⑥值班調(diào)度員立即通知通風(fēng)工區(qū)值班人員下井組織查明原因。
⑦立即匯報礦值班領(lǐng)導(dǎo)、礦通防副總、礦總工程師。
⑧在通風(fēng)工區(qū)值班人員未到達(dá)現(xiàn)場前,由瓦檢員和安監(jiān)員在現(xiàn)場監(jiān)護(hù)瓦斯變化情況,并及時向調(diào)度室匯報。
⑨通風(fēng)工區(qū)值班人員到達(dá)現(xiàn)場后,帶領(lǐng)瓦檢員、安監(jiān)員一起查明瓦斯的來源,涌出的濃度、壓力和工作面通風(fēng)情況,立即匯報礦調(diào)度室,具體的瓦斯處理工作,由通風(fēng)工區(qū)區(qū)長制定處理措施,匯報礦井技術(shù)負(fù)責(zé)人同意后,方可組織實(shí)施。
(三)、采掘工作面及其他巷道內(nèi),體積大于0.5m3空間內(nèi)積聚的瓦斯?jié)舛冗_(dá)到2.0%時:
1、現(xiàn)場管理人員立即匯報礦調(diào)度室和通風(fēng)工區(qū)值班人員。
2、附近20m內(nèi)作業(yè)人員必須立即停止工作,切斷電源,撤出人員。
3、安排跑片瓦檢員負(fù)責(zé)查明原因,瓦檢員在查明原因后,將現(xiàn)場實(shí)際情況及時報礦調(diào)度室和通風(fēng)工區(qū)值班人員,由通風(fēng)工區(qū)值班人員確定采取措施進(jìn)行處理,并負(fù)責(zé)組織實(shí)施。
(四)、采區(qū)回風(fēng)巷、采掘工作面回風(fēng)巷風(fēng)流中瓦斯?jié)舛瘸^1.0%或二氧化碳濃度超過1.5%時:
1、現(xiàn)場管理人員或作業(yè)人員必須立即停止工作,切斷電源,人員撤至主要進(jìn)風(fēng)巷道中,第一時間內(nèi)匯報調(diào)度室。
2、由班組長安排專人負(fù)責(zé)在巷道全風(fēng)壓風(fēng)流處設(shè)置警標(biāo)牌進(jìn)行警戒,嚴(yán)禁人員入內(nèi)。把便攜式瓦斯檢測報警儀懸掛在巷道警標(biāo)牌處(距頂板不大于300mm,距巷幫不小于200mm),由警戒人員檢測瓦斯?jié)舛龋⒘⒓聪蛘{(diào)度室進(jìn)行匯報。并立即通知其他距離較近人員迅速撤離到主要進(jìn)風(fēng)巷道中。
3、由跑片瓦檢員和安監(jiān)員一起在工作面回風(fēng)流與全風(fēng)壓風(fēng)流混合處新鮮風(fēng)流一側(cè),每隔5分鐘檢查一次回風(fēng)流瓦斯?jié)舛龋⒓皶r向礦調(diào)度室進(jìn)行匯報。
4、調(diào)度室值班人員接到匯報后,將超限的地點(diǎn)、時間、匯報人的姓名、現(xiàn)場的氣體情況作詳細(xì)的記錄。
5、通知沿途回風(fēng)巷道工作人員,停止工作、切斷電源,人員撤至新鮮風(fēng)流中,并在每個與回風(fēng)巷連通的巷道入口設(shè)置警標(biāo),禁止人員入內(nèi)。
6、調(diào)度室值班員立即通知通風(fēng)工區(qū)值班人員下井組織查明原因。
7、調(diào)度室值班員立即匯報礦值班領(lǐng)導(dǎo)、礦通防副總、礦總工程師。
8、調(diào)度室值班員負(fù)責(zé)通知各部門、單位及相關(guān)人員立即到調(diào)度室集合。
9、安全監(jiān)測系統(tǒng)地面中心站要記錄好超限斷電時間和現(xiàn)場的瓦斯變化情況及時向礦調(diào)度室匯報。
10、通風(fēng)工區(qū)值班人員到達(dá)現(xiàn)場后,在瓦斯和二氧化碳濃度都不超過1.5%的情況下,帶領(lǐng)瓦檢員、安監(jiān)員一起查明瓦斯的來源,涌出的濃度、壓力和工作面通風(fēng)情況,立即匯報礦調(diào)度室
⑾接到報警的部門、單位及相關(guān)人員立即到調(diào)度室集合,成立現(xiàn)場應(yīng)急處理小組,
由礦總工程師立即召*議,根據(jù)通風(fēng)工區(qū)值班人員匯報的井下現(xiàn)場情況,分析氣體的來源和大小,具體的瓦斯處理工作由通風(fēng)工區(qū)區(qū)長制定處理措施,匯報礦井技術(shù)負(fù)責(zé)人同意后,負(fù)責(zé)組織實(shí)施。
(五)、采掘工作面及其他巷道風(fēng)流中瓦斯?jié)舛纫虍惓G闆r達(dá)到3.0%時
1、現(xiàn)場管理人員或作業(yè)人員必須立即匯報調(diào)度室同時立即停止工作,切斷電源,人員撤至主要進(jìn)風(fēng)巷道中。
2、由班組長安排專人負(fù)責(zé)在巷道全風(fēng)壓風(fēng)流處設(shè)置警標(biāo)牌進(jìn)行警戒,嚴(yán)禁人員入內(nèi)。把便攜式瓦斯檢測報警儀懸掛在巷道警標(biāo)牌處(距頂板不大于300mm,距巷幫不小于200mm),由警戒人員檢測瓦斯?jié)舛龋⒘⒓聪蛘{(diào)度室進(jìn)行匯報。并立即通知其他距離較近人員立即撤離到主要進(jìn)風(fēng)巷道中。
3、由跑片瓦檢員和安監(jiān)員一起在工作面回風(fēng)流與全風(fēng)壓風(fēng)流混合處新鮮風(fēng)流一側(cè),每隔5分鐘檢查一次回風(fēng)流瓦斯?jié)舛龋⒓皶r向礦調(diào)度室進(jìn)行匯報。
4、調(diào)度室值班人員接到匯報后,將超限的地點(diǎn)、時間、匯報人的姓名、現(xiàn)場的氣體情況作詳細(xì)的記錄。
5、調(diào)度室值班人員在1分鐘內(nèi)匯報礦值班領(lǐng)導(dǎo)、礦通防副總、礦總工程師、礦長。
6、在5分鐘內(nèi)匯報煤業(yè)公司領(lǐng)導(dǎo)、通知救護(hù)大隊立即出動,進(jìn)行處理。
7、通知采區(qū)內(nèi)所有作業(yè)人員立即停止工作,沿途回風(fēng)巷道的工作人員,停止工作、切斷電源,人員撤至新鮮風(fēng)流中,并在每個與回風(fēng)巷連通的巷道入口設(shè)置警標(biāo),禁止人員入內(nèi)。
8、調(diào)度室值班員負(fù)責(zé)通知各部門、單位及相關(guān)人員立即到調(diào)度室集合。
9、接到報警的部門、單位及相關(guān)人員立即到調(diào)度室集合,成立現(xiàn)場應(yīng)急救援指揮部,由礦總工程師立即召開會議,根據(jù)現(xiàn)場的情況,分析氣體的來源和大小,制定相應(yīng)的處理措施,如果現(xiàn)場情況無法控制,匯報總指揮后,總指揮要迅速作出決定,全礦井是否停止生產(chǎn)、人員是否全部撤出。調(diào)度室值班人員下達(dá)命令關(guān)閉沿途回風(fēng)巷道以及現(xiàn)場的局部通風(fēng)機(jī)電源。
10、救護(hù)隊接到事故報告后,立即派救護(hù)隊員趕赴現(xiàn)場進(jìn)行檢查和監(jiān)護(hù),排放瓦斯前,必須制定安全排瓦斯措施,報礦井技術(shù)負(fù)責(zé)人批準(zhǔn),如果現(xiàn)場無法控制,不能立即處理時,必須在24h內(nèi)封閉工作面。
(六)、在處理瓦斯事故的過程中,現(xiàn)場作業(yè)的施工區(qū)隊人員,必須服從瓦檢員或通防管理人員的指揮。
三、一氧化碳傳感器報警應(yīng)急預(yù)案
(一)一氧化碳傳感器調(diào)校測試報警:
信息中心在對井下一氧化碳傳感器進(jìn)行正常調(diào)校和測試之前,必須提前匯報調(diào)度室及通風(fēng)區(qū),如未匯報調(diào)度室及通風(fēng)區(qū)就擅自進(jìn)行調(diào)校和測試造成一定后果的,要按事故進(jìn)行分析。
(二)一氧化碳傳感器報警:
當(dāng)安全監(jiān)測監(jiān)控系統(tǒng)一氧化碳傳感器報警時,信息中心要立即通知礦調(diào)度室及通風(fēng)區(qū),并由
通風(fēng)區(qū)和信息中心一同調(diào)查造成報警的原因,同時通風(fēng)區(qū)調(diào)度員要立即聯(lián)系井下瓦斯檢查員對現(xiàn)場一氧化碳情況進(jìn)行測定,并將測定的結(jié)果匯報通風(fēng)調(diào)度室,然后由通風(fēng)區(qū)調(diào)度員將井下測量結(jié)果反饋給調(diào)度室及信息中心。
1、外因火災(zāi)引起的一氧化碳超限
⑴、采掘工作面及其回風(fēng)流中因外因火災(zāi)導(dǎo)致一氧化碳濃度達(dá)到24ppm,一氧化碳便攜式報警儀超限報警后,井下現(xiàn)場作業(yè)人員必須立即停止工作,切斷電源,報告礦調(diào)度室。
⑵、礦調(diào)度室接到報警電話后,立即通知通風(fēng)工區(qū)值班人員和跑片瓦檢員前往井下現(xiàn)場組織查明原因,同時匯報礦值班領(lǐng)導(dǎo),礦總工程師,礦通防副總。礦調(diào)度接到報告后,應(yīng)立即按順序通知必須召集的人員和單位,同時設(shè)法通知可能受一氧化碳?xì)怏w威脅的危險區(qū)域人員的撤離。
⑶、在通風(fēng)工區(qū)值班人員和跑片瓦檢員未到達(dá)現(xiàn)場前,井下現(xiàn)場作業(yè)人員在保證自身安全的前提下,盡可能查清一氧化碳的來源、范圍、濃度、危害程度、威脅區(qū)域等情況,并向調(diào)度室匯報。
⑷、井下現(xiàn)場作業(yè)人員應(yīng)盡量保持現(xiàn)場的通風(fēng)方式和風(fēng)流方向,如能查清一氧化碳的來源(火源),在可能的情況下,應(yīng)在火源進(jìn)風(fēng)側(cè),在跟班領(lǐng)導(dǎo)和班組長的帶領(lǐng)下,利用一切可能的辦法和器材,撲滅火災(zāi)。
⑸、通風(fēng)工區(qū)值班人員到達(dá)現(xiàn)場后,應(yīng)帶領(lǐng)瓦檢員,安監(jiān)員一起查明一氧化碳的來源,濃度和工作面通風(fēng)情況,立即匯報礦調(diào)度室。如火勢太大,無法直接滅火,應(yīng)沿避災(zāi)路線撤退。并由礦調(diào)度室要求救護(hù)大隊立即出動滅火。
⑹、救護(hù)大隊接到事故報告后,應(yīng)按照>和>的規(guī)定立即行動,進(jìn)行滅火救災(zāi)工作。
2、內(nèi)因火災(zāi)引起的一氧化碳超限
⑴、采掘工作面及其回風(fēng)流中因內(nèi)因火災(zāi)導(dǎo)致一氧化碳濃度達(dá)到24ppm,一氧化碳便攜式報警儀超限報警后,井下現(xiàn)場作業(yè)人員必須立即停止工作,切斷電源,報告礦調(diào)度室。
⑵、礦調(diào)度室接到報警電話后,立即通知通風(fēng)工區(qū)值班人員和跑片瓦檢員前往井下現(xiàn)場組織查明原因,同時匯報礦值班領(lǐng)導(dǎo),礦總工程師,礦通防副總。礦調(diào)度接到報告后,應(yīng)立即按順序通知必須召集的人員和單位,同時設(shè)法通知可能受一氧化碳?xì)怏w威脅的危險區(qū)域人員的撤離。
⑶、在通風(fēng)工區(qū)值班人員和跑片瓦檢員未到達(dá)現(xiàn)場前,井下現(xiàn)場作業(yè)人員應(yīng)保持現(xiàn)場的通風(fēng)方式和風(fēng)流方向,并在保證自身安全的前提下,盡可能查清一氧化碳的來源、范圍、濃度、危害程度、威脅區(qū)域等情況,并向調(diào)度室匯報。
⑷、通風(fēng)工區(qū)值班人員攜帶紅處線火源探測儀等儀器到達(dá)現(xiàn)場后,應(yīng)帶領(lǐng)瓦檢員,安監(jiān)員一起查明一氧化碳的來源,濃度和工作面通風(fēng)情況,并匯報調(diào)度室。具體的處理工作,由通風(fēng)工區(qū)區(qū)長確定處理措施,匯報礦技術(shù)負(fù)責(zé)人同意后,并負(fù)責(zé)組織實(shí)施。
⑸、如必須在CO>24ppm,CH4>2%,T>35℃條件下處理內(nèi)因火災(zāi),必須由礦調(diào)度室匯報局調(diào)度室,要求公司救護(hù)大隊按照>和>的規(guī)定立即行動,進(jìn)行滅火救護(hù)工作。
7信息報告程序
礦調(diào)度室執(zhí)行24小時值班制度,并有專人負(fù)責(zé)應(yīng)急救援接警工作,具體聯(lián)絡(luò)方式如下:(附件)
7.1報警程序
⑴井下發(fā)生事故后,在事故地點(diǎn)及附近的人員應(yīng)利用電話或派出人員等方法,迅速將事故的性質(zhì)、發(fā)生地點(diǎn)、原因和危害程度向礦調(diào)度室匯報。井下其他區(qū)域的人員,在發(fā)現(xiàn)異常現(xiàn)象后,也應(yīng)及時向礦調(diào)度室匯報匯報。
⑵調(diào)度室及匯報人要根據(jù)事故的性質(zhì)和蔓延趨勢,以最迅速有效的方式,向可能受事故波及區(qū)域的人員發(fā)出警報通知。
⑶在搶救事故期間,井下救災(zāi)負(fù)責(zé)人應(yīng)隨時向礦調(diào)度室匯報災(zāi)區(qū)狀況和救災(zāi)工作進(jìn)展情況(如現(xiàn)有搶救力量、人員的情緒及身體狀況、救災(zāi)的現(xiàn)有條件、事故發(fā)展趨勢及后果、所采取的措施及所取得的效果等),也可對下一步搶救工作的開展提出建議和措施,取得礦井搶險組織部門指示和支持。
7.2接警、記錄程序
接警人員在接到報警后,必須迅速、準(zhǔn)確地向報警人員了解事故的性質(zhì)和規(guī)模等初始信息,并記錄在案。具體了解、記錄內(nèi)容見下表:
事故匯報人姓名
匯報時間
事故性質(zhì)
事故發(fā)生時間
事故發(fā)生地點(diǎn)
人員傷亡情況
事故地點(diǎn)通風(fēng)情況
事故可能波及的區(qū)域
是否伴生其它災(zāi)害
事故區(qū)域有何異常現(xiàn)象
備注
7.3通知程序
接警人員在接到報警后,首先要迅速向當(dāng)日值班領(lǐng)導(dǎo)匯報,然后迅速按照附表所列順序向應(yīng)急救援指揮部成員發(fā)出事故通知,以采取相應(yīng)的行動。接到災(zāi)害通知后,指揮部成員要立即趕赴指揮部集中,由總指揮統(tǒng)一安排工作,不準(zhǔn)擅離職守。
8事故的分級
按照監(jiān)測監(jiān)控系統(tǒng)故障范圍和事故嚴(yán)重程度,將監(jiān)測系統(tǒng)故障分為Ⅰ特別重大故障和Ⅱ級重大故障兩個事故狀態(tài)等級。
1、發(fā)生下列情況之一,為Ⅰ級特別重大故障狀態(tài):
①因監(jiān)控主機(jī)、傳輸接口、服務(wù)器、主要通訊光纜或其它因素發(fā)生嚴(yán)重故障,造成監(jiān)測監(jiān)控系統(tǒng)通訊信號中斷,全礦井的監(jiān)測盲區(qū)范圍達(dá)到事故前20%以上。
②因采區(qū)主通訊光纜、監(jiān)測分站、供電系統(tǒng)等因素發(fā)生故障,造成該采區(qū)監(jiān)測監(jiān)控系統(tǒng)通訊信號中斷,不能實(shí)施有效監(jiān)測監(jiān)控范圍達(dá)到事故前的40%以上。
2、發(fā)生下列情況之一,為Ⅱ級重大故障狀態(tài):
①安全監(jiān)控系統(tǒng)正常運(yùn)行過程中,因監(jiān)控主機(jī)、傳輸接口、主要通訊光纜或其它因素發(fā)生嚴(yán)重事故,造成監(jiān)測監(jiān)控系統(tǒng)通訊信號中斷,全礦井的監(jiān)測盲區(qū)范圍達(dá)到事故前5%以上,20%以下。
②因采區(qū)和通訊光纜、監(jiān)測分站、供電系統(tǒng)等因素發(fā)生故障,造成該采區(qū)監(jiān)測監(jiān)控系統(tǒng)通訊信號中斷,不能實(shí)施有效監(jiān)測監(jiān)控范圍達(dá)到事故前的20%以上,40%以下。
③因監(jiān)測監(jiān)控系統(tǒng)本身故障,造成與監(jiān)控系統(tǒng)相連的重要機(jī)電設(shè)施、設(shè)備發(fā)生大面積停電事故,不能及時處理的。
④傳感器、斷電器等監(jiān)測監(jiān)控設(shè)備,安裝數(shù)量不足、位置不符合規(guī)程規(guī)定的,并在8小時以內(nèi)不能補(bǔ)充完善的。
9應(yīng)急響應(yīng)
9.1、Ⅰ級特別重大故障事件響應(yīng)
1.1事件報告
①發(fā)生Ⅰ級特別重大故障事件時,監(jiān)測隊?wèi)?yīng)將故障范圍、現(xiàn)有狀態(tài)、影響范圍等有關(guān)情況立即報告應(yīng)急領(lǐng)導(dǎo)小組、生產(chǎn)調(diào)度室、通風(fēng)處和礦值班領(lǐng)導(dǎo)。
②應(yīng)急領(lǐng)導(dǎo)小組組長主持召開緊急會議,就有關(guān)重大應(yīng)急問題作出決策和部署,并立即啟動應(yīng)急預(yù)案。
③發(fā)生Ⅱ級特別重大故障事件時,應(yīng)及時召集、通知井下生產(chǎn)隊組、通風(fēng)部門采取安全預(yù)防措施。
1.2應(yīng)急處置
①監(jiān)測監(jiān)控系統(tǒng)的恢復(fù):發(fā)生Ⅰ級故障事件后,監(jiān)測(隊)部門要積極組織、盡快恢復(fù)安全監(jiān)控系統(tǒng)的正常運(yùn)行,并應(yīng)及時通知沁源縣安全監(jiān)控設(shè)備檢修中心。
②監(jiān)控系統(tǒng)恢復(fù)過程中,調(diào)度室與機(jī)電部門應(yīng)協(xié)調(diào)解決監(jiān)控系統(tǒng)的正常供電,閉鎖機(jī)構(gòu)的安全穩(wěn)定。
③監(jiān)控系統(tǒng)恢復(fù)過程中,通風(fēng)部門應(yīng)立即采取各種安全措施,加強(qiáng)瓦斯檢查;機(jī)電部門負(fù)責(zé)電氣安全管理。
④監(jiān)測隊立即啟動備用設(shè)備,按程序投入運(yùn)行,并及時分段檢查通訊線路,將故障范圍縮小到最低。
⑤監(jiān)控系統(tǒng)恢復(fù)過程中,監(jiān)測維護(hù)工在接到事故報警后,在當(dāng)班隊長的指揮下,立即進(jìn)行應(yīng)急處理,巡檢工作順延后推。
⑥地面檢修人員和材料管理員,必須保證各種設(shè)備、材料、儀器的性能完好,及時、足量提供供應(yīng)和運(yùn)輸。
9.2、Ⅱ級故障事件響應(yīng)
發(fā)生Ⅱ級故障事件后,由監(jiān)測隊?wèi)?yīng)急指揮機(jī)構(gòu)就有關(guān)應(yīng)急問題作出決策和部署,立即組織處理,同時立即向通風(fēng)處和生產(chǎn)調(diào)度室報告。
10應(yīng)急保障
1)、技術(shù)保障
全面加強(qiáng)技術(shù)支持部門的應(yīng)急基礎(chǔ)保障工作,集中全部的技術(shù)力量,成立重大故障處置小組,對故障進(jìn)行分析、決策和預(yù)測,增加技術(shù)培訓(xùn)和投入,研究、學(xué)習(xí)監(jiān)測監(jiān)控方面的先進(jìn)經(jīng)驗,不斷完善監(jiān)控系統(tǒng)重大故障應(yīng)急技術(shù)保障體系。
2)、裝備保障
監(jiān)測部門在積極利用現(xiàn)有裝備的額基礎(chǔ)上,根據(jù)應(yīng)急工作需要,建立和完善救援裝備數(shù)據(jù)庫和調(diào)用制度,配備必要的應(yīng)急救援裝備,并保證救援裝備始終處于隨時可正常使用的狀態(tài)。
3)、人員保障
加強(qiáng)監(jiān)測系統(tǒng)的準(zhǔn)確調(diào)度、安全生產(chǎn)管理,事故救援隊伍建設(shè),通過日常技能培訓(xùn)和模擬演練等手段提高維護(hù)人員的業(yè)務(wù)素質(zhì)、技術(shù)水平和應(yīng)急處置能力。
監(jiān)測部門各分管領(lǐng)導(dǎo)和技術(shù)人員,必須24小時保持通訊,接到事故報警后,立即趕到現(xiàn)場。
11培訓(xùn)和演習(xí)
1、培訓(xùn)
監(jiān)測部門各班組要認(rèn)真組織員工對應(yīng)急預(yù)案的學(xué)習(xí)和演練,通過日常培訓(xùn),來提高維修、維護(hù)技術(shù)人員的業(yè)務(wù)知識水平和應(yīng)對突發(fā)事件的能力。
2、演習(xí)
應(yīng)急領(lǐng)導(dǎo)小組辦公室至少每年協(xié)調(diào)組織一次應(yīng)急演習(xí),以加強(qiáng)和完善通風(fēng)、機(jī)電、監(jiān)測部門之間的協(xié)調(diào)配合工作。
12事故后期調(diào)查
監(jiān)測監(jiān)控系統(tǒng)發(fā)生重大故障后,由通風(fēng)區(qū)牽頭組織通風(fēng)、監(jiān)測、生產(chǎn)等部門,必須對事故發(fā)生原因進(jìn)行調(diào)查,應(yīng)客觀、公正、準(zhǔn)確地查清事故原因、發(fā)生過程、恢復(fù)情況、事故損失等。
附件:
救災(zāi)指揮人員名單、電話表
職務(wù) 姓名 聯(lián)系方式 內(nèi)部電話 手機(jī)號碼
篇2:醫(yī)學(xué)院水電氣故障應(yīng)急預(yù)案
醫(yī)學(xué)院水電氣故障應(yīng)急預(yù)案
根據(jù)《中華人民共和國安全生產(chǎn)法》、《川北醫(yī)學(xué)院特種設(shè)備、配電室安全應(yīng)急處置預(yù)案》,為提高我院水電氣故障處置的及時性、有效性,確保學(xué)院水電氣安全,穩(wěn)定的運(yùn)行,特制定本預(yù)案:
第一條 本預(yù)案適應(yīng)于發(fā)生在我院順慶及高坪校區(qū),對教學(xué)、科研、行政辦公及師生生活、學(xué)習(xí)影響較大的水電氣故障。
第二條 堅持以“預(yù)防為主 、安全第一”的方針,加強(qiáng)水電氣的安全管理,有效的防止重,特大事故的發(fā)生。
第三條 成立學(xué)院水電氣事故處置領(lǐng)導(dǎo)小組,負(fù)責(zé)組織指揮事故處置工作。(組織機(jī)構(gòu)及職責(zé)見預(yù)案細(xì)則。)
第四條 水電氣故障的分級,根據(jù)故障的不同程度將分為一、二、三級故障狀態(tài)等級。(具體分級情況見預(yù)案細(xì)則。)
第五條 故障的應(yīng)急處理:
1、停電事故的處理:高坪校區(qū)川北醫(yī)高壓專線停電,請示電業(yè)局后送高壓東果線供電;順慶校區(qū)西界線停電、可倒送家屬區(qū)的荊小線供電;科技大樓停電后可啟用自備發(fā)電機(jī)組供電。
2、火災(zāi)事故的處理:一是首先關(guān)閉電源及天然氣氣源。二是在自己滅火的同時,根據(jù)火勢情況報電話119火警。
3、一查詢、二報告、三處置、四通告。(具體查詢報告處置通告的具體內(nèi)容見預(yù)案細(xì)則。)
第六條 故障后期的處置:故障處置結(jié)束后,按照有關(guān)規(guī)定組成事故調(diào)查組對事故現(xiàn)場進(jìn)行技術(shù)分析,查明原因,分清責(zé)任,并編寫事故調(diào)查報告,提出預(yù)防及整改措施。
第七條 預(yù)案的管理與實(shí)施:隨著相關(guān)法律法規(guī)的逐步制定修訂和完善,部門職責(zé)的變化,以及在實(shí)施的過程中發(fā)現(xiàn)的問題,《預(yù)案》也將進(jìn)行修改和完善。
第八條 本《預(yù)案》報經(jīng)學(xué)院批準(zhǔn),自頒布之日起實(shí)施。
篇3:外國語中學(xué)電(貨)梯事故故障緊急救援預(yù)案
外國語中學(xué)電(貨)梯事故故障緊急救援預(yù)案
一、總則
(一)目的
為加強(qiáng)對電梯(貨梯)安全事故的防范,及時做好安全事故發(fā)生后的救援處置工作,最大限度地減少事故造成的損失,維護(hù)正常的社會秩序和工作秩序。
(二)編制依據(jù)
根據(jù)《中華人民共和國安全生產(chǎn)法》《特種設(shè)備安全監(jiān)察條例》的要求,結(jié)合本校(園)實(shí)際,特制定本預(yù)案。
(三)工作原則
本預(yù)案所稱安全事故,是指在本校電(貨)梯使用現(xiàn)場或維修保養(yǎng)的電梯突然發(fā)生的,造成或可能造成人身安全和財物損失的事故,事故類別包括:
(一)電梯(貨梯)困物故障;
(二)由于剪切、墜落等原因造成的人身傷亡事故;
(三)由于觸電等原因造成的人身傷亡事故;
(四)其它安全事故。
安全事故的具體標(biāo)準(zhǔn),按國家或行業(yè)、地方的有關(guān)規(guī)定執(zhí)行。
二、組織體系及職責(zé)任務(wù)
(一)成立電(貨)梯安全事故應(yīng)急救援指揮部(以下簡稱救援指揮部)。指揮長由校長擔(dān)任;副指揮長由分管安全的副校長擔(dān)任;各相關(guān)部門負(fù)責(zé)人為指揮部成員,參與現(xiàn)場搶險救援工作。
(二)設(shè)立現(xiàn)場救援組,由各安裝、維修班組人員兼職組成。組長由由分管校(園)長擔(dān)任,負(fù)責(zé)組織現(xiàn)場具體搶險救援工作;在指揮長到達(dá)現(xiàn)場之前,負(fù)責(zé)指揮現(xiàn)場搶險救援工作。
1.突發(fā)事件應(yīng)急救援組織機(jī)構(gòu)
報警:110
總指揮:z
副 總 指揮:z
通訊組:z
安全保衛(wèi)組:z
人員疏散組:z
后勤組:z
運(yùn)輸組:z
救援組:z
醫(yī)療組:z
2.主要職責(zé)
(1)組織有關(guān)部門按照應(yīng)急救援預(yù)案迅速開展搶救工作,防止事故的進(jìn)一步擴(kuò)大,力爭把事故損失降到最低程度。
(2)根據(jù)事故發(fā)生狀態(tài),統(tǒng)一布置應(yīng)急救援預(yù)案的實(shí)施工作,并對應(yīng)急處理工作中發(fā)生的爭議采取緊急處理措施。
(3)根據(jù)預(yù)案實(shí)施過程中發(fā)生的變化和問題,及時對預(yù)案進(jìn)行修改和完善。
(4)緊急調(diào)用各類物資、人員、設(shè)備。
(5)當(dāng)事故有危及周邊單位和人員的險情時,組織人員和物資疏散工作。
(6)配合上級有關(guān)部門進(jìn)行事故調(diào)查處理工作。
(7)做好穩(wěn)定秩序和傷亡人員的善后及安撫工作。
三、預(yù)防預(yù)警機(jī)制
(1)立即報告學(xué)校主要領(lǐng)導(dǎo),由主要領(lǐng)導(dǎo)批準(zhǔn),立即啟動本應(yīng)急救援預(yù)案,按照各自的職責(zé)和工作程序執(zhí)行本預(yù)案。當(dāng)校長不在時,由副校長負(fù)責(zé)組織指揮應(yīng)急搶險救援工作。
(2)指揮部根據(jù)事故或險情情況,立即組織或指令事故發(fā)生地組織調(diào)集應(yīng)急搶救人員、車輛、設(shè)備。組織搶救力量,迅速趕赴現(xiàn)場。
(3)立即組織或通知就近網(wǎng)點(diǎn),組織調(diào)集應(yīng)急搶救人員、車輛、設(shè)備。組織搶救力量,做好增援準(zhǔn)備。
四、應(yīng)急響應(yīng)
(1)正常事故故障工作
學(xué)校在每年春季開學(xué)初制定工作計劃,安排部署全年的知識宣傳和演練工作;通過舉辦專題展覽,知識競賽、召開主題班會等方法,加強(qiáng)對基本知識、應(yīng)急求生技能、法律法規(guī)的宣傳,切實(shí)提高廣大師生的安全防范意識;學(xué)校定期組織師生開展應(yīng)急和自救互救演練,增強(qiáng)應(yīng)急預(yù)案的針對性、指導(dǎo)性和實(shí)用性。
(2)緊急救援應(yīng)急行動
接到預(yù)(警)報后,領(lǐng)導(dǎo)小組立即進(jìn)入臨戰(zhàn)狀態(tài),召開會議,宣布進(jìn)入緊急預(yù)報期,布置救援工作,全體教職工應(yīng)做好應(yīng)急準(zhǔn)備工作。學(xué)校要采取緊急措施迅速有序地在教職工的帶領(lǐng)下將學(xué)生疏散到安全地帶。同時,要保證通訊線路的暢通,并隨時匯報救援工作情況。
五、應(yīng)急保障措施
(1)搶救方案根據(jù)現(xiàn)場實(shí)際發(fā)生事故情況,制定搶救方案,迅速投入開展搶救行動。
(2)傷員搶救立即與急救中心和醫(yī)院聯(lián)系,請求出動急救車輛并做好急救準(zhǔn)備,確保傷員得到及時醫(yī)治。
(3)事故現(xiàn)場取證救助行動中,安排人員同時做好事故調(diào)查取證工作,以利于事故處理,防止證據(jù)遺失。
(4)在救助行動中,救助人員應(yīng)嚴(yán)格執(zhí)行安全操作規(guī)程,配齊安全設(shè)施和防護(hù)工具,加強(qiáng)自我保護(hù),確保搶救行動過程中的人身安全和財產(chǎn)安全。
(5)緊急避難場所保障:學(xué)校要對本單位疏散的路線和臨時避難場所進(jìn)行規(guī)劃。
六、應(yīng)急終止
當(dāng)事故的評估預(yù)測達(dá)到起動應(yīng)急救援預(yù)案條件時,由應(yīng)急指揮長啟動應(yīng)急反應(yīng)預(yù)案。
(1)對事故現(xiàn)場經(jīng)過應(yīng)急救援預(yù)案實(shí)施后,引起事故的危險源得到有效控制、消除;所有現(xiàn)場人員均得到清點(diǎn);不存在其它影響應(yīng)急救援預(yù)案終止的因素;應(yīng)急救援行動已完全轉(zhuǎn)化為社會公共救援;應(yīng)急指揮長認(rèn)為事故的發(fā)展?fàn)顟B(tài)必須終止的。
(2)應(yīng)急救援預(yù)案實(shí)施終止后,應(yīng)采取有效措施防止事故擴(kuò)大,保護(hù)事故現(xiàn)場和物證,經(jīng)有關(guān)部門認(rèn)可后可恢復(fù)教育教學(xué)工作。
七、附則
應(yīng)急救援工作結(jié)束后,指揮部組織相關(guān)部門認(rèn)真進(jìn)行
總結(jié)、分析,吸取事故事件的教訓(xùn),及時進(jìn)行整改,并按照下列規(guī)定對有關(guān)單位和人員進(jìn)行獎懲。
1.對在應(yīng)急搶險救援、指揮、信息報送等方面有突出貢獻(xiàn)的個人,按有關(guān)規(guī)定,給予表彰和獎勵。
2.對瞞報、遲報、漏報、謊報重特大事故和突發(fā)事故中玩忽職守,不聽從指揮,不認(rèn)真負(fù)責(zé)或臨陣逃脫、擅離職守的人員,按照校有關(guān)規(guī)定,給予責(zé)任追究或處分。對擾亂、妨礙搶險救援的人員,由有關(guān)行政管理部門依法處理,構(gòu)成犯罪的,依法追究刑事責(zé)任。
本預(yù)案由zz市外國語中學(xué)制訂與解釋,上交市教育局安保科備案。